Multiple Build options:
Automatic motion sensing or Non Automatic ( manual button operation)
Manual Button: instant or 2 second delay with tone.
Evacuation Button : The optional evacuation whistle feature simulates the sound of the Acme Thundered whistle, and has a sequence of three blasts every 20 seconds.
Duration timer : After fifteen minutes it emits 5 low intensity bleeps,look at your gauge, from this time on the unit will emit 5 bleeps every 5 minutes infinite. This function will of course be overridden by the distress mode and zeroed by replacing the on/off key.
Temperature alarm: The temperature sensor is mounted on the PCB inside the case and it is there to monitor the internal temperature of the electronic components, The temperature sensor will operate if
the temperature inside the unit exceeds 70-80 degrees centigrade, however due to the thermal propagation through the case it may take some time for the unit to activate and warn the user to have the unit serviced.
Please be aware thatthis is not meant to be a life saving feature. |
The Diktron DSX alarm is specifically designed for users of breathing apparatus, And others working in potentially hazardous environments. The DSX unit will automatically emit a 96-dBA alarm should the wearer be rendered unconscious or trapped. A new concept in Distress Signal design, with many options to suit individual needs, the unit is built with the wearer in mind and will accommodate fixing to all B.A. sets. Made to a high specification and backed by the Diktron name, a name with standards you have come to expect and depend on.
Technical Specifications
Continouos Location Flashes.
Manual Alaram-Immediates or "TONE DELAY".
Movement Detector.
...PRE-ALARM AFTER 30 SECONDS.
...FULL ALARM 96 dBA AT 2M IN FREE AIR.
...RED LED FLASHES WITH DISTRESS SIGNAL.
Temperature sensor - optional.
Evacuation Whistle - Optional.
BA Duration time - Optional.
EMC tested and approved.
Small and low Profile Unit. 119.5 x 87 X 39mm.
Very Secure Fixings Available for vertical and horizontal Straps.
Removable key for tally Board Entry Control Systems.
Long operational Battery Life.
Low battery indication - Audio/Visual.
Certified Intrinsically safeto EEx ia IIC T4.
Many Optional build states available.
Designed to Meet Home office specification JCDD/38
Frequency Range 2.7Khz - 3.0Khz
Caution1 Flash every 1-Sec. alternating Sides & frint.
Movement monitor period 30 sec.
Pre-Alarm 10 Seca at 80dBA
Battery Duracell MN 1604
Automode Reset Indicator Amber Led 1 Sec Flashon Reset.
Full Alaram Sound JCDD 38 OR SOS.
BA Duration Timer**
Evacuation Whistle JCDD 40 Specification.
Size 119.5 x 87 x 39mm
Weight 300 Gms.
Battery Life (On Monitor) 157 Hrs. with MN1604
Low Battery Indication 1-Sec. Audio Tone & Red Led Every 2-Sec.
Certification Directive 76/117/EEC EGM, 89/336/ECC EMC
Certification Standard 50014:1997 + Amendments 1&2 EN50020:2002
Certification Level Ex II 2 G EEx ia IIC T4 CE1180
Design SPECIFICATION EXCEEDS JCDD 38
Certificate No Baseefa02ATEX0258
**AS OF DEC 1997 THE BA TIMER IS:
5 Beeps at 15 Mins and Then 5 Beeps Every 5 Min. Thereafter.
For Workers in the industrial sector Petrochemicals, Power Station, Gas and Electric, Construction Workers, Chemical cleaning companies, fire and rescue services and many more.
Weight 316.00g (Grams)
Size 87.00 x 39.00 x 119.50mm (W x D x L) |